Fire stopping must match the actual penetration configuration
Cables, pipes and other services pass through walls and floors that form part of a fire compartment. Each opening must be protected with a firestop system that matches the construction, the type and arrangement of services, the penetration dimensions and the required fire resistance.
Fire stopping is not simply filling an opening. The material is only one part of the system. Correct installation depends on the actual penetration configuration, the permitted field of application of the selected solution, required clearances and installation in accordance with the system documentation.


Fire stopping for cable, pipe and mixed penetrations
Cable penetrations
Fire stopping of individual cables, cable bundles, cable trays and the associated openings. The solution is selected according to penetration size, fill, service arrangement and the application conditions of the chosen system.
Pipe penetrations
Fire stopping of metal and plastic pipes through walls and floors. Selection takes account of pipe material and diameter, any insulation and the construction through which the pipe passes.
Mixed penetrations
Shared openings containing different services require a system suitable for the specific combination of cables, pipes, insulation, opening dimensions and required clearances.
EI 60, EI 90 and EI 120 – what do they mean for fire stopping?
In European fire-resistance classification, E refers to integrity and I to thermal insulation. The number indicates the time in minutes for which a specific tested and classified configuration meets the relevant criteria.
EI 60, EI 90 or EI 120 is not a universal property of a firestop foam, mortar, sealant or collar on its own. The required classification and suitable solution depend on the project, the construction and the actual service-penetration configuration.
Read more about tested firestop systems, EI classifications and correct installation →
Hilti and Promat firestop systems
We carry out firestopping using Hilti and Promat systems. Our workers have completed training for both systems. Each penetration is sealed with a suitable solution according to the project and the selected system documentation.
There is no single firestop product for every opening. The selected system must match the actual wall or floor construction, services, dimensions and arrangement of the penetration, as well as the project requirements.
What affects the scope and cost of fire stopping?
The cost of fire stopping cannot be determined reliably from the number of openings alone. The scope depends on the type and size of each penetration, wall or floor construction, services passing through it, required classification, selected system, quantity, access and site conditions.
For a project-specific quotation, drawings, a bill of quantities or penetration schedule, quantities and photographs of existing conditions are particularly useful. If some information is not yet available, the first technical review can be based on the data you already have.
Fire stopping in existing buildings and after service changes
In existing buildings, the actual condition of the penetration, construction, installed materials and service arrangement should be established first. Additional cables, larger cable bundles or changes to pipework can alter the original penetration configuration.
We carry out work where the existing condition can be established sufficiently and a suitable firestop system can be installed within its documented application conditions.
What should you send for a fire stopping quotation?
For a faster review, send the project information that is already available. The most useful items are:
- drawings, bill of quantities or penetration schedule
- photographs of existing conditions for refurbishment or existing buildings
- wall or floor construction and details of cables, pipes and insulation
- required fire-resistance classification where defined by the project
- quantities, project location and planned installation programme
TREE undertakes fire stopping projects across the EU. Depending on project scope, location and schedule, we can mobilise quickly for on-site execution.
Request a fire stopping quotationFrequently asked questions
What fire stopping work does TREE carry out?
We carry out firestopping using Hilti and Promat systems. Our workers have completed training for both systems. Each penetration is sealed with a suitable solution according to the project and the selected system documentation.
What affects the cost of fire stopping?
The main factors are penetration type and size, wall or floor construction, services, required classification, selected system, quantities, access and site conditions.
Do you work in existing buildings?
Yes, where the existing condition can be established sufficiently and a suitable firestop system can be installed within its documented application conditions.
Does TREE undertake fire stopping projects across the EU?
Yes. TREE undertakes fire stopping projects across the EU, subject to project scope, location, schedule and site conditions.
What information do you need for a quotation?
Drawings, a bill of quantities or penetration schedule, construction and service details, quantities, project location, programme and, for existing buildings, photographs where available.
Do you work with Hilti and Promat systems?